Abstract:
ABSTRACT
Background:
Cataract surgery quality is increasingly assessed not only by visual acuity outcomes but also by refractive accuracy. Achieving postoperative spherical equivalent within ±1.0 diopter is considered an international benchmark for surgical quality.
Objective:
To assess postoperative refractive outcome and associated factors among patients who underwent Manual Small Incision Cataract Surgery at Tibebe Ghion and Felege Hiwot Comprehensive Specialized Hospital, Northwest Ethiopia, 2025.
Methods:
An institution-based cross-sectional study was conducted among 148 patients who underwent cataract surgery at Tibebe Ghion Specialized Hospital and Felege Hiwot Comprehensive Specialized Hospital in Bahir Dar, Ethiopia, using consecutive sampling. Preoperative IOL was calculated using contact A scan ultrasound and manual keratometry at TibebeGhion and Retinomax at Felege Hiwot. Subjective refraction at 4–6 weeks postoperatively was used to determine the spherical equivalent. Data on demographics, ocular history, and surgical details were first collected on structured interviewer-administered questionnaire, then entered into Kobo Toolbox, cleaned in Excel, and analyzed using SPSS version 25. Logistic regression analysis was used to identify predictors of post operative refractive outcomes.
Results:
The mean postoperative spherical equivalent was −0.57 ± 0.94 D. Refractive accuracy within ±0.50 D and ±1.0 D was achieved in 47.3% (95% CI: 39.3–55.3) and 64.9% (95% CI: 57.3–72.5) of eyes, respectively. Best-corrected visual acuity ≥6/18 improved from 43.9% pre-correction to 64.9% post-correction. Increasing age independently increased the odds of poor refractive outcome by 5.4% per year (AOR = 1.054; 95% CI: 1.010–1.099; p = 0.015). Surgery performed by senior surgeons reduced the odds of refractive error > ±1.0 D by 70.7% compared with resident-performed surgery (AOR = 0.293; 95% CI: 0.113–0.762; p = 0.012).
Conclusion:
Only 64.9% of eyes achieved refractive accuracy within ±1.0 D, below the recommended benchmark of ≥85%. Older age and resident-performed surgery were significant predictors of suboptimal refractive accuracy.