| dc.description.abstract |
Abstract
Background: Internal fixation with cannulated screws is standard for femoral neck fractures, yet failure remains a critical challenge. This study evaluates clinical and radiographic factors associated with treatment success or failure.
Objective: The study aimed to assess the outcomes of femur neck fracture fixation and associated factors after cannulated hip screw done at TGSH from Oct 2022 to Oct 2024.
Methods: We retrospectively reviewed 32 patients who underwent cannulated hip screw fixation for femoral neck fractures. Outcome was defined as treatment success (union) or failure (nonunion, malunion, or fixation failure). Variables such as age, sex, Garden and Pauwels classifications, comorbidities, and reduction method (open vs. closed) were included in the analysis. Statistical analysis utilized Fisher’s Exact Test for categorical variables and binary logistic regression to calculate Odds Ratios (OR) with 95% Confidence Intervals (CI). Effect sizes were quantified using Cramer’s V.
Results: Eight treatment failures (25%) were observed. Patients undergoing open reduction had 11.63 times higher odds of failure compared to those treated with closed reduction (OR 11.63; 95% CI: 0.13–0.558). While not statistically significant, Garden classification (V=0.218) and Pauwels classification (V=0.190) demonstrated moderate clinical associations with failure.
Conclusion and recommendation: Open reduction was associated with a higher failure rate, likely serving as a proxy for complex, inherently unstable fractures that resist closed maneuvers. Despite the small sample size, the moderate effect sizes of displacement and shear angle underscore the need for anatomical reduction. Surgeons should anticipate higher complication rates when open reduction is required for femoral neck fractures. |